Description
Honeywell ADE Accenta Mini GEN4 with LED Keypad
8 Zones
Each one is separately identified on the keypad and provides ample security detection for most domestic properties.
3 part set programs
Allows three programmed setting levels dependent on the people in the property or the level of protection required, eg. night-time with upstairs detectors off and perimeter detectors on.
Simple set readers for ease of operation – Optional
Up to 4 stylish readers can be used to SET/UNSET the system with the option of using a proximity keyfob. Ideal for young, elderly or infirm.
Personal attack facility
PA buttons may be used to activate the system in an emergency. An additional PA facility exists on the remote keypads.
Remote keypads for added flexibility Up to four slimline keypads can operate the system from any point in the property.
New LCD Keypad – Optional
The LCD remote keypad operates with the Optima Gen4 intruder systems.
Up to four LCD keypads can be connected to the system. The large 2×16 characters with backlight display provide a full status indication and the keypad plays entry and exit tones.
Fire Zone
Zones 7 and 8 may be programmed as a 24 Hour Fire Zone operating all of the time except during engineer mode.
250-event log
The last 250 events to have occurred are stored in the memory and can be displayed, with their date and time, on the LCD remote keypad screen.
Duress Code
Allows the user to unset the system and silence the alarm under duress, using a second code that will communicate an alarm to an Alarm Receiving Centre.
Chime
Can be used to select a low security chime alarm for various areas of your house, even when the main alarm is turned off. When a door is opened or a detector triggered in an area set to chime, the control panel will deliver a low-volume æbing-bongÆ sound to alert you. This is ideal for areas that require low level monitoring.
Zone names selectable from the library
A new option accessible from the LCD remote keypad allows the installer to assign descriptors from a 22-name library to each of the eight zones.
Built-in tamper control
To protect all wiring and detectors in the system from an authorised access including the control panel and remote keypad covers.
Accenta Mini End Station
On board keypad & display | No |
Simple Set Interface | Yes |
RKP Indication | |
8 Zones | +ve loop, fully programmable |
Tamper | -ve loop globa |
PA | -ve loop |
Bell Output | 12V latching, timed 1 to 99 minutes |
Strobe Output | 12V |
Extension Speake | Max two 16 Ohm |
Entry/Exit Timers | Programmable 10 to 990 seconds |
Zone Input Delay | 300 or 800ms selectable |
Set +ve Output | Source 10mA, sink 40mA |
CPU Current consumption (standby) | 45mA |
RKP Current consumption (standby) | 25mA |
Low voltage output | 13V +/- 5% |
Rechargeable battery | Up to 2.1Ah |
Communicator outputs | Yes |
Communicator output types | Intruder, PA, Fire, Abort, Set |
PCB Fuses | 1 x 1.6A, 3 x 1.0A |
Mains input fuse | 125mA anti-surge |
Total current output | 1 Amp when supported by fully charged battery |
Mains supply voltage | 230V +/- 10% |
RKP wiring | 6 core Max distance 100m |
Dimensions CPU (h x w x d) | 200 x 253 x 55mm |
Accenta LED Remote Keypad
Keypad Type | LED |
Operating Voltage | 11 to 15V |
Current Consumption | 40mA |
Temperature Range | 0 to 50°C |
Construction | White 3mm polycarbonate |
Dimensions (h x w x d) | 85 x 122 x 28mm |
Reviews
There are no reviews yet.